Despite the length of this article, it is not a comprehensive guide to Building Biology. It is but a basic guide. For a comprehensive look into Building Biology, there are text books on the subject, such as “Prescriptions for a Healthy Home – 4th Edition” by Baker LaPorte & Banta.

Many people today are diagnosed with Autoimmune diseases, Cancer, Hyper Chemical Sensitivities, and more; and that number continues to grow as a result of not only the food in the United States being poisoned by unnecessary toxins, but also our building products.

Many of the products we use to construct buildings and build houses today are very convenient, helping to save time and money, but that comes at a price to our health. From the glues that hold together plywood, to the chemicals that are mixed to create spray foam insulation, drainage pipes, vinyl siding and asphalt roofs, these toxins off gas, in many cases, for many years, and are one of the hidden causes of cancer and autoimmune diseases.

Hi. My name is Seth Harris, the owner of Harris Home Builders. In this article, we are going to go over the basics of what Building Biology is and how to build a healthy home using Building Biology standards.

Building Biology and Ecology began in 1970, when the Gesundes Bauen – Gesundes Wohnen’ (Healthy Building – Healthy Living) Society in Germany began collecting all existing knowledge on healthier and more sustainable building, including building practices that had been disappearing steadily over the previous fifty years. Today, it is considered the international standard for building Healthy Homes. Other programs in the US don’t even compare.

Building Biology goes deep into how the products we build with not only effect the environment around us (Building Ecology), but also how it affects our health (Building Biology). It may not be obvious to many people, but VOC’s from paints, primers, glues, insulation, and more negatively affect our health and immune systems, while many products, considered to be “green” negatively affect the health of the environment, such as composite decking and vinyl siding.

Building Biology follows 25 rigorous principles as follows:

Site Selection: Locate homes away from sources of contamination, pollution, radiation, and noise.

Low-Density Housing: Favor low-density housing with sufficient green space.

Regional Planning: Design infrastructure for short distances to work, shopping, and education.

Environmental Harmony: Build in a way that respects the natural environment and local ecosystem.

Social Responsibility: Create housing that promotes social well-being and community connectivity.

Building Materials

6. Natural Materials: Use natural, non-toxic, and breathable building materials.

7. Pleasant Scent: Ensure a neutral or pleasant smell, free from toxic off-gassing.

8. Low Radioactivity: Choose materials with low, natural radioactivity levels.

9. Sustainable Sourcing: Prioritize regional materials and avoid exploiting scarce resources.

10. Waste Reduction: Minimize waste throughout the life cycle of the building.

Indoor Environment and Climate

11. Humidity Control: Regulate indoor air humidity naturally, aiming for a healthy balance.

12. Moisture Control: Ensure low moisture content in new buildings to prevent mold.

13. Thermal Insulation: Balance thermal insulation with heat retention.

14. Temperature Optimization: Optimize indoor surface and air temperatures.

15. Indoor Air Quality: Promote excellent air quality through natural ventilation.

16. Radiant Heating: Use radiant heat for comfortable, energy-efficient heating.

Electromagnetic and Radiation Safety

17. Natural Radiation: Minimize alterations to natural background radiation.

18. EMF Protection: Avoid human-made electromagnetic (AC) and radiofrequency radiation.

19. Lighting: Maximize natural daylight and use flicker-free, natural lighting sources.

20. Acoustics: Provide effective protection against noise and vibration.

Occupant Well-being and Design

21. Physiological Design: Use ergonomic principles and natural proportions for design.

22. Sensory Experience: Nurture the senses of sight, smell, and touch.

23. Water Quality: Ensure the best possible quality of drinking water.

24. Safety from Toxins: Minimize exposure to mold, bacteria, dust, and allergens.

25. Holistic Approach: Balance all factors to create a truly restorative living space.

Site Selection

From the top, Site selection involves choosing land to build on that is mostly surrounded by nature. Avoid areas near cities, power plants, manufacturing plants and cell towers to avoid pollution from vehicle exhaust, factory exhaust and electromagnetic radiation as much as possible.

Choose neighborhoods in rural areas where houses tend to have at least a small forest between yards, but that are also relatively close to schools, shopping centers and all your basic necessities. But also, choose a neighborhood as opposed to a fully private house in the middle of nowhere. Unless, of course, you enjoy being a recluse. In general, socialization is healthy.

Below is a basic discourse on material selections.

Concrete

Let’s start with the Foundation. Concrete mixtures today include a toxic chemical soup of both natural materials and manufacturing byproducts, such as coal fly ash and blast-furnace slag (from steel manufacturing) to make them cheaper, and often include steel rebar which disrupts the natural electromagnetic environment.

These chemicals are known to off-gas creating a toxic breathing environment, as do the typical waterproof sealers they need to be sealed with to prevent moisture from getting in.

It is possible to source healthy, all natural concrete, but it must be specifically requested. You can request a Concrete Contractor to order a “Clean Mix” following these directives:

Must contain 100% pure Portland Cement (Type I/II) paired with natural aggregate (washed sand and crushed local stone). You must explicitly write “No Fly Ash” and “No Slag” into the structural notes on the building plans to ensure no substitutes are used. If a natural pozzolan is required for strength, allow only Calcined Clay or Metakaolin.

If rebar must be used, request Fiberglass (GFRP) or Basalt composite rebar. Basalt rebar is made from melted volcanic rock. Both Fiberglass and Basalt are non-conductive, stronger than steel, entirely rust-proof and electrically neutral, preserving the natural ambient geomagnetic fields.

When it comes to waterproofing, there are two good options. Rather than the typical black tar, made from toxic petro-chemicals, opt for EPDM Rubber that is mechanically fastened to the concrete wall, or have a sodium silicate solution sprayed or painted onto the wall. Rubber is a natural compound made from Rubber Trees and Sodium Silicate is a harmless chemical substance that reacts with the Calcium Hydroxide in the concrete to form a crystalline structure that blocks water penetration while still allowing the concrete to breath.

If you want to ensure that the concrete will be waterproof all the way through and through from the moment it’s poured, you can request a Hydrophilic Crystalline Admixture such as Krystol Internal Verification, KIM, or Xypex Admix. This turns the entire thickness of the foundation in a self-healing, waterproof barrier from day one. When micro-cracks form down the road and water tries to seep in, the water activates the chemicals, causing them to instantly grow long, non-toxic, needle like crystals that permanently block water flow.

Framing

Building a house exterior typically involves stick framing with wood. This can be tricky. Although it is building biology compliant to use natural softwoods for framing, if not cared for properly, or built fast enough, these woods can end up growing mold before the house is finished, which can continue to affect the household for life.

Metal framing is strictly against building biology standards because it negatively affects the natural electromagnetic environment inside the building. The best alternatives is to build with natural Stone, or Concrete, which can come as a poured concrete wall, prefabricated concrete wall, or as Concrete Bricks. If building with Stone or Bricks, you must ensure the concrete bricks and the mortar is building biology compliant.

Concrete bricks should be AAC blocks rather than CMU blocks. Mortar should be Pure Lime Mortar or Lime Putty. Paired together, this maintains wall breathability to prevent moisture build up, and thus, mold growth, and helps to maintain indoor air humidity. If Concrete poured walls, or prefabricated Concrete are to be used, simply ensure the concrete meets the same standards as the foundation described above.

Wood can still be used if properly cared for, and it still must be used on the interior once the exterior is fully sealed. In general, it is the only option for floors/ceilings and Roofing Systems unless you build super expensive brick domes. To properly care for wood pre-build, it must be stored in a way that prevents it from warping and getting wet, while allowing every member to breathe open air.

After the wood is delivered, each individual piece should be inspected and then carefully placed so there is a minor gap between them all, both horizontally and vertically, and they should be stored under a roof, even if that roof is only a tarp. However, if a tarp is used, ensure it does fully surround the wood – covering it completely so the rain doesn’t fall on it, but leaving the sides open so the water vapor coming up from the ground can evaporate away from the wood.

Any wood that is discovered to have mold should be discarded or returned to the supplier and replaced. Once the wood is being set in place on the structure, all the members are far enough away that a single day of rain will not cause them grow mold before the water evaporates. However, if it rains for several days in a row, this could cause mold to grow.

To avoid this, instead of using softwoods, you can use locally sourced hardwoods. This dramatically increases the cost, but hardwoods are naturally resistant to both insects and mold growth.

When it comes to subfloors and exterior sheathing, the golden standard is natural wood planks, such as 1×8 or 1×6. They should be placed perpendicular to floor joists and roof rafters, and on a 45-degree angle on exterior walls for shear strength. However, if local codes require plywood, then typical exterior grade plywood is acceptable as they have the least amount of glue with the least amount of harmful chemicals that off gas the fastest.

For decks, typically Pressure Treated wood is used. However, this is strongly discouraged by building biology because it contains toxic arsenic. Instead, it is recommended to use local Hardwoods coupled with more stringent building practices to prevent water trapping, or aluminum or steel framing. While metal framing is discouraged for the house structure itself because it disrupts the internal electromagnetic environment, metal framing for decks does not because it exists on the exterior of the house.

While we’re talking about decks, composite decking is also strongly discouraged, not only because it contains toxic VOC’s, but also because it contaminates the environment, does not biodegrade, and is not recyclable. Instead, natural woods should be used, and preferably without using stains or paints, allowing the wood to breath, which also extends the life of the wood decking and railing. Paints and stains don’t prevent water from getting into the wood, but they do prevent it from getting back out, which accelerates rot.

Roofing and Siding

Asphalt Roofs and Vinyl Siding are strictly prohibited in building biology. They are both made with toxic petro-chemicals that continue off gassing for many years in the hot summer heat, and they are not biodegradable or recyclable.

The best alternatives for Asphalt Roofs are Slate Roofs, Concrete Tiles or Terra Cotta Tiles. Metal Roofs are acceptable with the caveat that you avoid wireless service in the house as the metal roof reflects that back into the house amplifying the toxic load. Wood shingles can be used, but their life span is much shorter. Perhaps the most healthy option is a living garden roof lined with EPDM Rubber, although they are also the most expensive to repair or replace in the event of a leak.

As for siding, untreated and unpainted Wood Siding is the golden standard. Cedar is the best option, but there are also thermally modified wood options available which are made to be naturally water and insect resistant. It’s best to avoid sealants, stains or paints, as they all contain off gassing VOC’s. Natural wood turns an attractive silver gray as it ages, and leaving it natural keeps it breathable for life which inhibits mold growth.

Metal Siding can be used with the same caveat as metal roofing. If stone or brick siding is desired, building biology recommends using a mortarless brick option that is physically fastened to the wall, or a stone veneer that is physically fastened with an air gap if against a wood wall to retain breathability, so moisture doesn’t build up and cause mold growth.

Electrical and Plumbing

The best option for water supply is Copper of Surgical Grade Stainless Steel (Type 316L). Surgical Grade Steel is very expensive, but is the golden standard, especially if you will have Hard Well Water to deal with as it will be impervious to corrosion. If that is cost prohibitive, however, it can be used only to get the well water to the water softener, and then Copper can be used from there.

You’ll want to avoid PEX piping as it not only off gasses toxic chemical but leaches them into your water supply along with microplastics. However, if you have to use PEX, or you require a more budget friendly option, then it is recommended you use only PEX-a, such as Uponor AquaPEX, which used a peroxide manufacturing method that produces the lowest relative off gassing profile.

For drainage, you’ll want to avoid the typical PVC and ABS pipes, as they are also made with toxic chemicals and must use more toxic chemicals to bond them that off gas, and they have no noise suppression for the water that flows through them. The golden standard for building biology is Hubless Cast Iron which are mechanically fastened and provide excellent sound supression.

If Cast Iron is too heavy or cost prohibitive, a good alternative is Polypropylene Acoustic Drainage Systems. They are much cleaner than PVC and ABS containing no harmful chlorine or plasticizers and they install with push-to-fit rubber O-ring sockets. They are also heavily reinforced to provide acoustic sound-deadening properties similar to cast iron.

The Golden Standard for electrical wiring is Metal-Clad Armor Cable, such as HCF (Health Care Facility) MCAP Steel or Aluminum MC Cable. They contain the standard copper conductors wrapped in a continuous, flexible metal armor jacket that acts as a physical barrier trapping 100% of the AC electric fields. Standard Romex wire prevents electric shock by touch, but still allow the electric field to travel up to 6-8 feet from the wires.

If Romex must be used, however, the best alternative is to install them inside of Solid Metal Conduit such as Electrical Metallic Tubing (EMT) steel conduit. This perfectly shields the electrical field and also has the added benefit of making it easy to replace or add wiring in the future.

For data and network wires, the golden standard is Double-shielded Twisted Pair (S/FTP) Cat7 or Cat8 Ethernet. Standard Cat6 does not adequately shield the electrical field. The rule of thumb is to use shielded RJ45 metal connectors and patch panels. If the shields are not connected to a grounded patch panel, the metal jacketing acts as an ungrounded antenna, worsening the ambient electrical environment.

For cable and audio wires, the standard is Quad Shielded RG6 Coaxial cable. Standard coaxial cable has dual layer shielding, but quad shielded variants feater two layers of aluminum foil and two layers of braided aluminum shielding. This fully contains the high-frequency signals running to your cable modem or TV box.

Standar speaker wires are unshielded plastic cords that easily pick up and radiate ambient electromagnetic noise. Specify Shielded 2-conductor audio wire, such as Belden or Gepco shielded audio cables to ensure audio delivery remains pure and electromagnetically quiet.

These are some Design Rules to have your electrician follow to ensure installation maintains building biology standards:

Strict Separation of data and power lines. Never run power cables parallel to ethernet or cable lines in the same wall cavity or joist space. Keep them at least 12 inches apart. If they must cross each other, ensure they cross at a 90-degree angle to minimize electromagnetic induction.

Twist the Conductors: When purchasing wiring, opt for cables where the hot and neutral wires are tightly twisted around one another. This spatial arrangement causes the opposing magnetic fields of the hot and neutral lines to cancel each other out.

Isolate the Sleeping Zones: Create dedicated radial circuits for bedrooms. Use a centralized Demand Switch (remote disconnect) at the main electrical panel. When the last bedside lamp is turned off at night, the demand switch automatically drops the voltage in the bedroom walls to zero, providing an electromagnetically clean environment for deep sleep.

Banish Plastic Junction Boxes: Use only galvanized steel electrical boxes for your outlets and light switches. Plastic boxes allow electric fields to leak out into the room right at the outlet interface. A properly grounded steel box contains the field.

Ensure the Electric Meter is installed away from any bedroom or the primary living area as they produce large electromagnetic fields. The best place to install it is on the far side of the garage.

Insulation

The best option for insulation is Hempcrete. It is naturally insect, mold and fungi resistant without any chemical treatment, and is the most ecologically sustainable as it grows quickly without the need for pesticides.

Another good option is Sheep’s Wool. It can hold up to 33% of its own weight in water without feeling wet making it excellent at providing humidity control without losing any insulation value. However, it needs to be treated with non-toxic borate to make it pest resistant.

Expanded Cord Insulation is also a great choice as it is naturally rot-proof, impervious to pests, and maintains its structural integrity and insulation value for decades. 100% bio-based, completely free of added chemicals, binders, or flame retardants, using it’s own natural resin (suberin) to bind the granules under steam heat.

Finally, there is Borate Treated Blown in Cellulose. Made from recycled newspaper, cellulose has very low embodied energy and provides excellent sound dampening (acoustic protection). To be building biology compliant, you must specify 100% borate-treated cellulose. Avoid cellulose blends that use ammonium sulfate, which can react with moisture to create unpleasant ammonia off gassing.

If none of these are an option for you, a good middle ground is Rockwool insulation. It provided excellent sound dampening as well as fire, mold and pest resistance, but you must Specify formaldehyde-free or ultra-low VOC lines (look for Declare Red List Free labels or GREENGUARD Gold).

Spray foam insulation is strictly prohibited in building biology. They are made with toxic petro-chemicals and act as a total vapor barrier (trapping moisture inside walls), release toxic gasses during installation and curing, and contain hazardous halogenated flame retardants.

Wall Finishing

Drywall might be the golden standard for cheap building practices, but it’s not the best material for building biology standards. Standard drywall is faced with heavy paper made of cellulose. If a wall cavity experiences even minor moisture or high humidity, that paper facing becomes the perfect breeding ground for toxic molds.

Furthermore, moisture-resistant (greenboard) or mold-resistant (purpleboard) drywalls achieve their ratings by being saturated with biocides, fungicides, and silicone plasticizers. These semi-volatile organic compounds (SVOCs) can slowly off-gas into the indoor air loop over time.

Drywall installation relies heavily on modern joint compounds and adhesives. Premixed drywall mud often contains biocides and preservatives to give it a shelf-life, while drywall glues used on studs frequently rely on polyurethane chemical bases that off-gas heavily during curing.

Building Biology approved alternatives include:

Clay Boards (Clay Panels): The gold standard in building biology. These are pre-manufactured interior panels made of clay, reed, and hemp fibers. They install similarly to drywall but offer unmatched humidity-buffering capabilities, contain zero toxins, and absorb indoor odors naturally.

Solid Wood Paneling: Locally sourced, unadulterated tongue-and-groove wood boards finished with natural oils or waxes provide excellent acoustic protection and a warm indoor climate.

Traditional Three-Coat Lime or Gypsum Plaster: Applied directly over brick, stone, CMU, or wood lath. Pure interior lime plaster is highly alkaline, making it completely immune to mold growth without needing chemical additives.

Flooring

Composite flooring is out of the question for a Building Biology Healthy Home. Not only are not biodegradable or recyclable, but they are made of toxic petro-chemicals that off gas into the home environment. Carpets are also terrible because they are dust and moisture magnets which are prone to growing mold.

Solid Hardwood, or Engineered Hardwood and Bamboo are the most common flooring options that are building biology compliant. However, to remain compliant, they should never be glued down, only nailed or screwed, and they should never be finished with stain or polyurethane, but rather with natural plant based oils and waxes (such as linseed oil, tung oil, or beeswax) so the wood remains vapor-permeable and dynamic.

Top Compliant Engineered Wood Choice: Sustainable Hardwood Flooring from Kahrs Original, Harmony is a three-layer engineered flooring that uses a glueless mechanical interlocking system, removing the need for toxic adhesives altogether. It is designed explicitly to remain stable over radiant heating loops and complies with ultra-strict European E0 and California CARB2 emission standards.

Top Compliant Bamboo Choice: Sustainable Bamboo Flooring from GBS, Wide Plank Click Engineered Strand Bamboo Flooring is an exceptionally durable, FSC-certified strand bamboo option compressed without added urea-formaldehyde. It clicks together as a floating floor, eliminating subfloor glue.

True Natural Linoleum is also a good option. Real linoleum is a completely bio-based material. It is entirely different from toxic, petroleum-based vinyl sheet flooring. It is made by pressing a mixture of linseed oil, pine rosin, wood flour, limestone, and natural pigments onto a woven jute backing. It is naturally antistatic and antimicrobial.

Forbo Marmoleum Composition Tile (MCT) is highly recommended by building biologists. It features a 100% natural, bio-based content and avoids added urea-formaldehyde. When installing tiles, ensure you pair them with a verified low-VOC, solvent-free adhesive such as Forbo Sustain 1195.

Natural Cork Flooring is harvested from the bark of cork oak trees without harming the tree, cork is an exceptional humidity buffer, provides acoustic dampening, and feels naturally warm underfoot. You’ll want to choose either solid cork tiles glued down with a natural water-based contact cement, or glueless floating click planks that utilize a natural cork core rather than standard toxic HDF/MDF fiberboards. Ensure the finish is a natural wax or an ultra-low-emission water-based coat.

Untreated Terracotta, Brick, or Natural Stone provide massive thermal mass (perfect for radiant floor heating systems) and carry a near-zero risk of toxic emissions or chemical off-gassing. However, like structural masonry, stone and tile floors must be set using lime-based or pure cement mortars free from synthetic polymer additives. Seal the porous tile with breathable, natural stone oils rather than synthetic acrylic sealants.

Look for products carrying independent, third-party verifications like GREENGUARD Gold, FloorScore, or a Declare Red List Free tag.

Cabinets and Trim

To be building biology compliant, cabinetry and interior trim must adhere strictly to the rules of zero added formaldehyde, low-to-no volatile organic compounds (VOCs), and natural wood sourcing.

Conventional cabinets and trim are notorious indoor air polluters. Standard cabinets are typically made of cheap particleboard or Medium-Density Fiberboard (MDF) held together by urea-formaldehyde glues that off-gas for years. Standard trim is frequently made of highly glued composite woods or synthetic plastics like PVC, which trap moisture and harbor toxic semi-volatile compounds.

When designing your kitchen or bathroom, prioritize materials that bypass synthetic glues altogether, or choose brands that utilize plant-based binders.

Solid Wood Casework (The Gold Standard). Built entirely from planks of real, sustainably harvested timber (such as oak, maple, or birch). It uses mechanical joints and minimal non-toxic wood glue rather than chemical resins. To remain compliant, you’ll need to specify unfinished boxes and door faces, then finish them on-site with natural oils (like tung or linseed oil) or milk/clay-based paints.

Formaldehyde-Free Plywood (Columbia PureBond). If your budget or layout requires sheet goods rather than solid wood, specify cabinet boxes built exclusively with Columbia Forest Products’ PureBond Plywood. Instead of toxic urea-formaldehyde, it utilizes a soy-based adhesive system inspired by how mussels stick to rocks in nature. It is widely recognized by building biologists and is featured by healthy cabinetry customizers like Green Building Supply.

Stainless Steel or Aluminum Cabinets. Metal cabinets are naturally 100% emission-free, zero-VOC, radiation-free, and inert. They do not require finishes that off-gas and are completely immune to water damage or mold colonization. They are excellent for clean, modern aesthetics, or for individuals with severe Multiple Chemical Sensitivities (MCS).

Compliant Big Brands & RTA Alternatives:

KraftMaid (Upgraded): Available at major retailers, KraftMaid offers an all-plywood cabinet box upgrade. Their factory-cured finishes are highly baked on, which significantly accelerates and reduces the off-gassing timeline compared to lower-tier brands.

IKEA (Budget Hybrid): IKEA cabinets utilize strict European emission targets. While they use melamine/particleboard cores, their lacquered or melamine-faced door lines (like Veddinge) encapsulate the core well, partially blocking inner emissions.

Baseboards, crown molding, and door/window casings should remain completely “breathable” and natural.

Unfinished Solid Hardwood Trim (such as Poplar, Pine, or Maple) is 100% natural, carbon-neutral, and free of processing chemicals. Brands like NewMouldings Poplar Unfinished Moulding Trim 0.75″H x 3.5″W x 42″D – Sustainable Hardwood offer completely raw, American-sourced hardwood trim lines. Because they ship completely unfinished, you avoid standard industrial chemical primers altogether.

Eco-Wise and No-Added-Formaldehyde (NAF) MDF: If solid wood is cost-prohibitive, you must skip standard big-box store MDF and explicitly seek out NAF (No Added Formaldehyde) or LEED-compliant eco-molding lines, such as Metrie (with their Eco-Wise initiative) and Westcoast Moulding manufacture specialty MDF moldings using advanced resin technologies that emit virtually zero urea-formaldehyde and leverage recycled wood fibers.

All trim should be nailed directly to the studs (do not use liquid construction adhesives) and coat it with a breathable mineral paint, lime wash, or zero-VOC water-based finish.

What to Avoid Completely:

Standard Industrial MDF/Particleboard: Avoid unsealed or low-grade composites; they act as a massive sponge for moisture and off-gas heavily.

PVC / Plastic Moldings: Avoid synthetic vinyl trim or faux-wood plastic crown moldings. They prevent walls from drying out and generate high electrostatic fields that attract dust and biological allergens.

Toxic Trim Adhesives: Never allow your trim installers to use heavy solvent-based construction adhesives to stick baseboards to your drywall or plaster. Insist on a mechanical fastener (finish nails/screws) only approach.

Wall Finishes

The best building biology-compliant wall finishes are 100% natural, plastic-free, antistatic, and vapor-permeable (“breathable”) materials that allow the underlying wall to buffer moisture and regulate indoor humidity.

Conventional interior paints create a synthetic vinyl or acrylic latex film over the wall. This film acts like a thin plastic wrap, trapping moisture in the wall cavity, generating static electricity that attracts dust, and slowly off-gassing harmful volatile organic compounds (VOCs). Building biology strongly recommends bypassing standard paints in favor of these mineral- and plant-based finishes:

1. Pure Clay Plaster (The Gold Standard)

Why it complies: Clay plaster is the ultimate finish for indoor climate regulation. It is highly hygroscopic, meaning it continuously absorbs excess indoor humidity and releases it when the air is dry, naturally keeping indoor humidity in the ideal 40% to 60% range.

Benefits: It contains zero petrochemicals, binders, or synthetic toxins. It is naturally antistatic (it does not attract airborne dust or allergens), absorbs and neutralizes indoor odors, and can be easily repaired with just water.

Top Compliant Choice: Meoded Moroccan Clay Matte Plaster – Gallon 4.4 Kilo is formulated from real clay and natural minerals. This trowel-applied plaster provides dynamic texture, long-term vapor permeability, and an entirely inert, zero-emission surface for interior drywall, stone, or block walls.

2. Clay Paints

Why it complies: If plastering is outside your budget or skill level, clay-based liquid paints are the closest equivalent that can be applied with a standard roller or brush.

Benefits: True clay paints completely swap out acrylic copolymers for benign plant- or mineral-based binders (like cellulose or plant starches). They have a flat, earthy matte finish, excellent breathability, and practically zero odor during or after application.

Top Compliant Choice: The BioShield Paint Company manufactures a renowned line of BioShield Clay Paint. Free from formaldehyde, solvents, glycol, and heavy metals, it provides an outstanding humidity-buffering finish that is safe even for individuals with extreme chemical sensitivities.

3. Mineral Silicate Paint

Why it complies: Instead of drying into a sticky film over the wall, silicate paint works through a chemical process called silicification. The paint permanently bonds and petrifies with the mineral substrate (plaster, drywall, brick, or CMU).

Benefits: Highly open to vapor diffusion, completely non-flammable, and entirely free of VOCs or plasticizers. Because it is highly alkaline, it acts as a natural antimicrobial barrier that counteracts mold, moss, and algae without needing toxic synthetic biocides.

Top Compliant Choice: For an ultra-premium, durable finish that easily meets the strictest global building biology requirements, look to Keim Soldalit White from KEIM. This advanced sol-silicate paint is absolutely emission-free and can be applied directly to bare mineral walls or even directly over old organic/acrylic paints without a primer.

4. Natural Lime Wash

Why it complies: Made simply from crushed limestone fired at high temperatures, mixed with water, and aged into a putty. It is colored exclusively with natural earth pigments.

Benefits: Lime wash is highly breathable and has an extremely high pH level. This natural alkalinity makes the wall completely immune to mold and bacteria, making it an exceptional finish for kitchens, bathrooms, or high-humidity zones.

5. Plant-Based Natural Paints (AURO)

Why it complies: Brands that focus entirely on biogenic chemistry avoid petrochemicals completely.

Top Compliant Choice: AURO Natural Paints are a staple of European Baubiologie. They utilize an innovative, proprietary biogenic binding agent called Replebin®. This binding agent allows their paints to be 100% biodegradable, highly abrasion-resistant, and so natural that the dried paint is safely compostable.

Summary Avoidance List:

When completing your wall details, explicitly reject vinyl wallpapers (which create a moisture-trapping plastic barrier) and standard commercial “low-VOC” or “zero-VOC” latex paints. While safer than older paints, conventional zero-VOC options still utilize a synthetic acrylic-plastic binder that forms a non-breathable layer and can contain harmful semi-volatile chemical preservatives (SVOCs).

Air Ventilation and Circulation

In building biology, it is best to build an airtight house and add mechanical ventilators to exchange filtered fresh outdoor air with stale indoor air. This might seem confusing when we we’ve talking about using “breathable” materials throughout the rest of this article.

What it means for a material to be breathable is that it allows moisture to pass through, so that moisture doesn’t build up and cause mold to grow, and helps regulate the indoor humidity. But the house can, and should, be built with no air gaps to prevent drafts which also allow moisture to build up and grow mold.

But when a house is air tight, that means it doesn’t exchange air with the outdoors well, which, if not properly ventilated can cause stale air to build up along with dust and other contaminants. So, a proper air exchange unit must be installed for this purpose.

Air ventilators are typically installed in attic spaces and draw in fresh air from the outdoors, filter that air and circulate it through the house. It may be tempting to combine this with an HVAC system for heating and cooling the air simultaneously, but this is not recommended by building biology as it has a tendency to cause more noise and create a drafty house.

Instead these systems should be kept separate, but proper care must be given to the particular conditions of the climate area. For example, in cold dry climates a Heat Recovery Ventilator (HRV) can be used to retain indoor humidity. But in hot and humid or 4 season climate zones, it’s better to use an Energy Recovery Ventilator (ERV) which helps to regulate the humidity levels as needed.

To remain building biology compliant, Zero-leakage Static Plate Cores should be used, rather than thermal wheels which mix a small percentage (3 – 5%) of the stale, indoor air, with the incoming outdoor air. A static plate core ensures a physical separation between the two.

You also want to ensure that your unit uses Electronically Commutated Motors (ECM) with low EMF radiation to minimize the electromagnetic field radiation, as opposed to cheap AC Motors. Additionally, the units main control panel should be hardwired, rather than wireless.

You’ll want to ensure your system uses a Medical Grade Filtration System such as MERV 13 or HEPA, which requires a high pressure intake fan. Standard systems come with a MERV 8 filter and standard intake fan which only filter large dust particles.

It’s important that you use Hygienic, Food-Grade Ducting systems (for both your air exchange and HVAC systems). Avoid flexible, ribbed plastic or acoustic fiberglass-lined ducts which attract dust and other contaminants and can’t be cleaned. Opt for smooth-bore, rigid galvanized steel (spiral ducting) or food-grade, anti-static, anti-microbial radial semi-rigid PE piping. Ensure they also feature accessible inspection hatches so the system can be visually checked and cleaned.

If you live in an environment that gets down to freezing temperatures, then it’s important to prevent frost from building up when the incoming freezing air crosses the warm and humid indoor air in the ventilation system. The typical solution for this is to add an integrated electric pre-heater or a geothermal brine loop on the fresh air intake to warm the air above freezing temperature before it enters the core.

Best brands to use are Zehnder ComfoAir and Brink Climate Systems Flair Series. Panasonic Intelli-Balance or BalancedHome Elite is a good alternative if paired with an upgraded MERV 13 filter, a hardwired controller and smooth, rigid ductwork to bring it into compliance.

Heating and Cooling

Hydronic Radiant Systems are the Gold Standard for heating. Building biology principle #9 dictates that homes should prefer radiant heat over convective heat. Radiant heating warms objects and people directly through infrared waves rather than blowing hot, dusty air around the room.

In-Floor or In-Wall Hydronic Loops: Water pipes embedded inside concrete slabs, lime plaster, or clay walls provide the most comfortable thermal climate.

Compliant Tech: Stiebel Eltron Hydronic Heating / Ground Source Heat Pump Tech is highly valued by building biologists. These systems cleanly heat water using geothermal energy or air-source heat pumps, transferring warmth to the floors without using turbulent fans.

Health Benefit: Zero air movement means zero circulation of dust, pet dander, or mold spores. It preserves the natural, healthy balance of negative air ions in the breathing zone.

Cooling is challenging in building biology because lowering air temperatures below the dew point naturally extracts moisture, creating a risk for hidden mold inside mechanical units.

Option A: Ductless Mini-Splits with Variable-Speed Inverters:

Compliant Brand: Mitsubishi Electric Deluxe Wall-Mounted Mini-Split (MSZ-FS) with 3D i-See Sensor.

Why it complies: It uses variable-capacity inverter technology, allowing it to run constantly at a low speed rather than blasting on and off. This controls humidity accurately and keeps acoustics dead silent.

The Maintenance Catch: Mini-splits must be opened and deep-cleaned annually. Their plastic interior drip pans and fan wheels are highly prone to dust buildup and mold colonization if neglected.

Option B: Hydronic Radiant Cooling Panels:

For advanced builds, cool water can be run through ceiling or wall panels. This must be paired with an ERV that handles dehumidification perfectly to prevent any condensation from forming on the walls.

HVAC systems are generally discouraged, but if you must, here are the 4 Imperative HVAC Installation Rules. If your design requires a traditional ducted heat pump setup, you can significantly increase its compliance by enforcing these strict mechanical protocols:

Isolate Electromagnetic Fields (EMF): Large air handlers and heat pump compressors generate powerful magnetic and electrical fields. Locate the main indoor mechanical equipment away from bedroom walls to protect sleeping areas from electromagnetic radiation.

Banish Fiberglass Duct Liners: Ensure no ducts are lined internally with fiberglass insulation, which can degrade and release microscopic glass shards into the air stream. All insulation must remain on the outside of the metal ductwork.

Install Deep MERV 13+ Filtration: Standard 1-inch filters do little to protect human lungs. Specify a media housing unit capable of holding a 4-inch thick MERV 13, MERV 16, or HEPA filter to capture fine particulates, pollen, and outdoor smoke.

No Short-Cycling (Perfect Sizing): Never let a contractor guess your equipment size based on square footage. Insist on a rigorous Manual J Load Calculation. An oversized system will cool the house too quickly without removing humidity, turning your home into a cold, damp, mold-prone environment.

Vastu Architecture

If you are planning on building a Building Biology compliant home, might I suggest you also incorporate Vastu Architecture, the highest standard of using natural proportions and shapes to best effect healthy living. All Vastu Architecture incorporates all the principles of Building Biology.

Click here to learn more about Vastu Architecture.

Click Here to learn more about Building Biology.

Click here to learn more about us.

If you are interested in building a Custom Home with Building Biology standards, feel free to contact us at 860-817-7191, email me at Seth@HarrisHomeBuilders.com or Click Here to schedule your Free Consultation.

Seth Harris

Founder, Harris Home Builders. Custom homes, additions, and whole-home remodels in the Farmington Valley and on the Connecticut shoreline.